Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
Clin Oral Investig ; 28(3): 201, 2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38453706

RESUMO

OBJECTIVES: The aim of this study was to assess cone beam computed tomography (CBCT) as a root canal anatomy diagnostic tool by comparison with micro-CT gold-standard. MATERIALS AND METHODS: 216 two-rooted mandibular molars were first scanned in a CBCT device (200 µm voxel size) and posteriorly in a micro-CT scanner (19.61 µm). The volumes were sequentially screened to classify main root canal anatomy according to Vertucci classification, and for the presence of lateral canals and apical deltas, in both mesial and distal roots. RESULTS: Both methods revealed a higher prevalence of Vertucci Type II and IV in the mesial root, and Vertucci Type I in the distal root. The percentage of agreement for main root canal anatomy classification between CBCT and micro-CT scores was high (85.2%). CONCLUSION: Sensibility to detect both lateral canals and apical deltas with CBCT was low. These results attest to the fact that minor anatomical changes might be difficult to identify with CBCT imaging, hampering its diagnostic value.


Assuntos
Cavidade Pulpar , Mandíbula , Cavidade Pulpar/diagnóstico por imagem , Cavidade Pulpar/anatomia & histologia , Microtomografia por Raio-X , Mandíbula/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico/métodos , Raiz Dentária/diagnóstico por imagem , Raiz Dentária/anatomia & histologia
2.
Aust Endod J ; 2023 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-37849412

RESUMO

This study aims to assess the influence of root canal preparation, irrigation needle design and its placement depth in the irrigation flow of confluent canals during syringe irrigation. A mandibular molar presenting two confluent canals in its mesial root was sequentially prepared and scanned by micro-computed tomography after mechanical preparation up to ProTaper Next system sizes X2 (25/.06v), X3 (30/.07v) and X4 (40/.06v). In each of the root canal preparation models, a side-vented and an open-ended needle at 5, 3 and 2 mm from the working length were included, and irrigation flow was assessed by a validated computational fluid dynamics model. The results revealed that the irrigant flowed out of the confluent canals mainly through the canal that did not have the needle. Apical penetration and renewal of the irrigant were most efficiently achieved with the use of a 30G open-ended needle and a 30/.07v preparation.

3.
J Endod ; 49(9): 1207-1215, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37468061

RESUMO

The loss of periodontal tissue support and vertical buccal bone loss in apico-marginal defects can often be mistaken for features indicative of vertical root fractures and this study reports thirteen cases with persistent symptomatic apical periodontitis, apico-marginal defects, and large periapical lesions that were managed with endodontic microsurgery in conjunction with bone grafts and barrier placements with a follow-up period of up to 9 years. At the recall sessions, all cases were asymptomatic with radiographical success with only 2 cases exhibiting residual apical radiolucency, but with evident reduction in the lesion size, indicative of healing. This study highlights the potential of utilizing endodontic microsurgery combined with guided tissue regeneration that proved effective in stimulating the regeneration of periodontal tissue in cases of apico-marginal defects that can lead to favourable long-term outcomes.


Assuntos
Microcirurgia , Periodontite Periapical , Humanos , Regeneração Tecidual Guiada Periodontal , Periodontite Periapical/diagnóstico por imagem , Periodontite Periapical/cirurgia , Cicatrização , Periodonto
4.
Dent J (Basel) ; 10(12)2022 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-36547035

RESUMO

Irrigating solutions play an important role in the eradication of intracanal microbes and debris dissolution during endodontic treatment. Different combinations of solutions and protocols have been advocated, with sodium hypochlorite (NaOCl), ethylenediamine tetra acetic acid (EDTA), and chlorhexidine (CHX) remaining the most widely used ones by many clinicians. Although these solutions provide efficient inorganic dissolution and antimicrobial capacity, their use has also been reported to cause undesired effects on root dentin composition and mechanical and biomechanical properties, such as microhardness, surface roughness, bond strength, and matrix metalloproteinase (MMP) activity. Several corroborating studies attribute these changes in mechanical properties of dentine to the use of irrigating solutions, and there are limited reports on how the solutions affect the expression of MMPs, which may be a correlating link to understanding the role of these enzymes in dentin collagen and changes in the mechanical properties of dentin. Hence, using the basis of several studies from the literature, the objective is to comprehensively review the influence of individual and combined irrigating solutions on root dentine structure and the activity of the MMPs.

5.
Polymers (Basel) ; 14(17)2022 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-36080644

RESUMO

The objective was to evaluate the effect of different root canal irrigating solutions on the activity of matrix metalloproteinases (MMPs), and correlation to the push-out bond strength (PBS) and nanoleakage expression (NL) in the root dentin. Seventy-two single-rooted teeth were treated endodontically and distributed into four groups (n = 6 for in-situ zymography, n = 10 for PBS, and n = 2 for NL per group) according to the irrigating solutions used: (I) saline (S); (II) 5.25% sodium hypochlorite (SH); (III) 5.25% SH + 10% citric acid (CA); and (IV) 5.25% SH + 10% CA + 0.2% chlorhexidine (CHX). After root canal obturation, post space was prepared to receive the glass fiber post. Dual-cure resin was used for luting and light polymerization was performed. The root/fiber post assemblies were sectioned and subjected to in situ zymography, and PBS and NL expression analysis tests. The enzymatic activity was quantified and expressed as a percentage of the green fluorescence, while fractographic evaluation was performed after PBS with a stereomicroscope, and data were statistically analyzed at p < 0.05. The zymography analysis shows high expression of MMPs in the middle third of the root in all groups, while the most abundant activity of MMPs following the irrigating solutions is observed in groups I and III, where saline and citric acid are used, respectively. Inversely, group IV, where chlorhexidine is the final rinse, records the lowest MMP activity with the highest PBS, and the statistical analysis of the groups are ranked as: IV > II > III > I (p < 0.05). The combination of SH, CA, and CHX results in lower expression of MMPs and higher push-out bond strength of fiber posts to root dentin, with no difference seen in the nanoleakage expression (p > 0.05); hence, this irrigation regime with chlorhexidine as a final rinse is more favorable than other combinations in ensuring optimal adhesion to root dentine.

6.
Int Endod J ; 55(12): 1394-1403, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36040378

RESUMO

AIM: This study aimed to experimentally validate a computational fluid dynamics (CFD) model, using micro-particle image velocimetry (micro-PIV) measurements of the irrigation flow velocity field developed in confluent canals during irrigation with a side-vented needle. METHODOLOGY: A microchip with confluent canals, manufactured in polydimethylsiloxane was used in a micro-PIV analysis of the irrigation flow using a side-vented needle placed 3 mm from the end of the confluence of the canals. Velocity fields and profiles were recorded for flow rates of 0.017 and 0.1 ml/s and compared with those predicted in CFD numerical simulations (using a finite volume commercial code - FLUENT) for both laminar and turbulent regimes. RESULTS: The overall flow pattern, isovelocity and vector maps as well as velocity profiles showed a close agreement between the micro-PIV experimental and CFD predicted data. No relevant differences were observed between the results obtained with the laminar and turbulent flow models used. CONCLUSIONS: Results showed that the laminar CFD modelling is reliable to predict the flow in similar domains.


Assuntos
Hidrodinâmica , Agulhas , Simulação por Computador , Reologia , Endodontia
7.
Restor Dent Endod ; 47(2): e17, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35692226

RESUMO

Endodontic microsurgery is a predictable treatment option when orthograde treatment or retreatment is unsuccessful or unfeasible. However, when there is a gross compromise of periapical bone, achievement of bone regeneration after the surgical procedure may be hampered. In such cases, the application of guided tissue regeneration principles, with adjunctive use of leukocyte platelet-rich fibrin to fill the bone defect as a bone substitute and as a membrane to cover the site, provides a cost-effective solution with the benefits of accelerated physiological healing and reduced post-surgical pain and discomfort. This case report presents 2 cases of endodontic microsurgery of the upper lateral incisors with loss of buccal cortical plate, where platelet-rich fibrin was successfully applied.

8.
Materials (Basel) ; 15(11)2022 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-35683270

RESUMO

A multimethod study was conducted to assess the differences between original (PG-OR) and counterfeit (PG-CF) ProGlider instruments regarding design, metallurgical features, and mechanical performance. Seventy PG-OR and PG-CF instruments (n = 35 per group) were evaluated regarding the number of spirals, helical angles, and measuring line position by stereomicroscopy, while blade symmetry, cross-section geometry, tip design, and surface were assessed by scanning electron microscopy. Energy-dispersive X-ray spectroscopy and differential scanning calorimetry were used to identify element ratio and phase transformation temperatures, while cyclic fatigue, torsional, and bending testing were employed to assess their mechanical performance. An unpaired t-test and nonparametric Mann−Whitney U test were used to compare instruments at a significance level of 5%. Similarities were observed in the number of spirals, helical angles, blade symmetry, cross-sectional geometries, and nickel−titanium ratios. Measuring lines were more reliable in the original instrument, while differences were noted in the geometry of the tips (sharper tip for the original and rounded for the counterfeit) and surface finishing with PG-CF presenting more surface irregularities. PG-OR showed significantly more time to fracture (118 s), a higher angle of rotation (440°), and a lower maximum bending load (146.3 gf) (p < 0.05) than PG-CF (p < 0.05); however, maximum torque was similar for both instruments (0.4 N.cm) (p > 0.05). Although the tested instruments had a similar design, the original ProGlider showed superior mechanical behavior. The results of counterfeit ProGlider instruments were unreliable and can be considered unsafe for glide path procedures.

9.
Braz Dent J ; 33(1): 112-118, 2022.
Artigo em Português | MEDLINE | ID: mdl-35262549

RESUMO

This case describes the treatment and follow-up of a mandibular molar in an 18-year-old female with a periapical cyst. Thus, it becomes important to know which options should we take when faced with a clinical situation that we cannot resolve through conventional methods, and which techniques and approaches we have to achieve treatment success. This case showed the treatment plan and follow-up, by the use of CBCT images, from a previously treated mandibular molar with a large periapical abscess and cystic lesion, in which, the first treatment plan approach was to make the endodontic retreatment. During the chemo-mechanical preparation the presence of permanent intracanal purulent exudate made it impossible to dry the canals, impeding obturation of the root canal system. Due to this clinical situation, a surgical approach was performed with the intention of reduce this permanent exudate and to execute a decompression technique. Clinical findings, periapical radiographs and cone beam computed tomographic, indicated almost complete resolution of the radiolucency, after a one-year follow-up.


Este relato de caso descreve o tratamento e acompanhamento de um molar inferior em uma jovem de 18 anos com cisto periapical. Assim, torna-se importante saber quais opções devemos tomar diante de uma situação clínica que não podemos resolver pelos métodos convencionais, e quais técnicas e abordagens temos para alcançar o sucesso do tratamento. Este caso mostrou o plano de tratamento e acompanhamento, por meio de imagens de tomografia computadorizada de feixe cônico (TCFC), de um molar inferior previamente tratado com grande abscesso periapical e lesão cística, no qual, a primeira abordagem do plano de tratamento foi fazer o retratamento endodôntico. Durante o preparo químico-mecânico a presença de exsudato purulento intracanal permanente impossibilitou a secagem dos canais, impedindo a obturação do sistema de canais radiculares. Devido a essa situação clínica, foi realizada abordagem cirúrgica com a intenção de reduzir esse exsudato permanente e executar uma técnica de descompressão. Após um ano de acompanhamento, os achados clínicos e radiográficos indicaram processo de reparo.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Periodontite Periapical , Adolescente , Tomografia Computadorizada de Feixe Cônico/métodos , Exsudatos e Transudatos , Feminino , Humanos , Dente Molar , Tratamento do Canal Radicular/métodos
10.
Braz. dent. j ; 33(1): 112-118, jan.-fev. 2022. graf
Artigo em Português | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1364478

RESUMO

Resumo Este relato de caso descreve o tratamento e acompanhamento de um molar inferior em uma jovem de 18 anos com cisto periapical. Assim, torna-se importante saber quais opções devemos tomar diante de uma situação clínica que não podemos resolver pelos métodos convencionais, e quais técnicas e abordagens temos para alcançar o sucesso do tratamento. Este caso mostrou o plano de tratamento e acompanhamento, por meio de imagens de tomografia computadorizada de feixe cônico (TCFC), de um molar inferior previamente tratado com grande abscesso periapical e lesão cística, no qual, a primeira abordagem do plano de tratamento foi fazer o retratamento endodôntico. Durante o preparo químico-mecânico a presença de exsudato purulento intracanal permanente impossibilitou a secagem dos canais, impedindo a obturação do sistema de canais radiculares. Devido a essa situação clínica, foi realizada abordagem cirúrgica com a intenção de reduzir esse exsudato permanente e executar uma técnica de descompressão. Após um ano de acompanhamento, os achados clínicos e radiográficos indicaram processo de reparo.


Abstract This case describes the treatment and follow-up of a mandibular molar in an 18-year-old female with a periapical cyst. Thus, it becomes important to know which options should we take when faced with a clinical situation that we cannot resolve through conventional methods, and which techniques and approaches we have to achieve treatment success. This case showed the treatment plan and follow-up, by the use of CBCT images, from a previously treated mandibular molar with a large periapical abscess and cystic lesion, in which, the first treatment plan approach was to make the endodontic retreatment. During the chemo-mechanical preparation the presence of permanent intracanal purulent exudate made it impossible to dry the canals, impeding obturation of the root canal system. Due to this clinical situation, a surgical approach was performed with the intention of reduce this permanent exudate and to execute a decompression technique. Clinical findings, periapical radiographs and cone beam computed tomographic, indicated almost complete resolution of the radiolucency, after a one-year follow-up.

11.
Iran Endod J ; 17(1): 39-47, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36703875

RESUMO

The aim of this study was to describe a new strategy, consisting of the use of cone-beam computed tomography (CBCT) in the planning and intraoperative stages of root canal treatment (RCT), associated with the use of radiopaque gutta-percha markers, as an auxiliary tool in the location of severely calcified root canals. Three cases involving anterior and posterior teeth with severe calcification of the root canal were submitted to initial periapical radiographic and CBCT evaluations for diagnosis and planning of the operative steps. In a first intervention, when the location of the canal orifice was not successful, radiopaque markers were inserted in the suggested position of canal orifice with the aid of magnification and the use of ultrasonic devices, in order to perform an intraoperative CBCT analysis that allowed dynamic navigation through the static position of markers. The association of intraoperative CBCT with radiopaque markers allowed the location of the canal orifice and the following RCT execution. The use of CBCT in two different moments of RCT allowed the diagnosis of three-dimensional anatomical variations of root canal. Add, when associated with the use of radiopaque gutta-percha markers, acted as an auxiliary tool in the location of the canal orifice of calcified canals. Therefore, the presented strategy provides the clinician the precision that cases with calcification require and give an important contribution to treatment predictability.

12.
Int Endod J ; 55(1): 30-37, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34676902

RESUMO

AIM: To describe the prevalence of periapical lesions, root canal treatments and coronal restorations on teeth adjacent to either implant- or natural tooth-supported crowns using cone-beam computed tomography (CBCT) assessment compared to nonadjacent teeth. METHODOLOGY: A total of 1249 CBCT volumes were screened by five pre-calibrated observers in 11 health centres. A step-by-step screening protocol was implemented and reviewed every 3 months, and mandatory setting characteristics were established for all CBCT scans using dedicated visualization software. Intra- and inter-rater reliability tests were conducted. The prevalence of periapical lesions, root canal treatments and coronal restorations was recorded on both teeth adjacent and nonadjacent to implant- (predictor 1) or natural tooth-supported crowns (predictor 2). A binary logistic model (Generalizing Estimating Equations test) was used to verify whether the prevalence of periapical lesion, root canal filling and the tooth restorative status are altered when the assessed tooth is adjacent or not to an implant-supported crown (predictor 1); or to a natural tooth-supported crown (predictor 2). Odds ratio and confidence intervals for the dependent variables at both predictors were obtained. The significance level was set at .05. RESULTS: A global sample of 22 899 teeth was included. Compared to nonadjacent teeth, the prevalence of periapical lesion, root canals treatments and restorative procedures when adjacent to implant-supported crowns was 10.7%, 19.6% and 22.9% higher, respectively, and when adjacent to tooth-supported crowns was 19.3%, 35.6% and 37.4% higher respectively. These results were significant only for variables root canal filling and coronal restoration (p < .0001). Odds ratio to present root canal treatment is 2.57 times higher (CI 1.95-3.39, p = .0001) when the tooth is adjacent to implant-supported crown and 4.39 times (CI 3.49-5.53, p = .0001) when adjacent to tooth-supported crown, whilst for restorative procedure, the odds are, respectively, 1.63 (CI 1.29-2.06, p = .0001) and 2.30 (CI 1.92-2.76, p = .0001). CONCLUSIONS: Teeth adjacent to both implant- and natural tooth-supported crowns were associated with a higher frequency of root canal filling and coronal restorations.


Assuntos
Cavidade Pulpar , Periodontite Periapical , Estudos Transversais , Coroas , Humanos , Prevalência , Reprodutibilidade dos Testes
13.
Clin Oral Investig ; 26(3): 3299-3310, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34860307

RESUMO

OBJECTIVES: To compare the design, metallurgy, mechanical performance, and canal preparation of 5 rotary systems. MATERIAL AND METHODS: A total of 735 25-mm NiTi instruments (sizes 0.17[0.18]/.02v, 0.20/.04v, 0.20/.07v, 0.25/.08v, 0.30/.09v) from ProTaper Gold, ProTaper Universal, Premium Taper Gold, Go-Taper Flex, and U-File systems were compared regarding overall geometry and surface finishing (stereomicroscopy and scanning electron microscopy), nickel and titanium ratio (energy-dispersive spectroscopy), phase transformation temperatures (differential scanning calorimetry), mechanical performance (torsional and bending tests), and unprepared canal surface (micro-CT). One-way ANOVA and Mood's median tests were used for statistical comparisons with a significance level set at 5%. RESULTS: Stereomicroscopic analysis showed more spirals and high helical angles in the Premium Taper Gold system. All sets of instruments had symmetrical spirals, no radial lands, no major defects, and an almost equiatomic ratio between nickel and titanium elements, while differences were observed in their tips' geometry and surface finishing. At room temperature (20 °C), DSC test revealed martensitic characteristics for ProTaper Gold and Go-Taper Flex, and mixed austenite plus R-phase for the Premium Taper Gold, while ProTaper Universal and U-Files had full austenitic characteristics. Overall, larger instruments had higher torque resistance and bending load values than smaller ones, while a lack of consistency and mixed values were observed in the angle of rotation. The 0.25/.08v and 0.30/.09v instruments of ProTaper Universal and U-File had the highest maximum torques, the lowest angles of rotation, and the highest bending loads than other tested systems (P < .05). No significant difference was noted regarding the untouched root canal walls after preparation with the tested systems (P > .05). CONCLUSIONS: Although differences observed in the overall geometry and phase transformation temperatures have influenced the results of mechanical tests, unprepared canal surface areas were equivalent among systems. CLINICAL RELEVANCE: Root canal preparation systems with similar geometries might present different mechanical behaviors but equivalent shaping ability.


Assuntos
Ligas Dentárias , Preparo de Canal Radicular , Ligas Dentárias/química , Desenho de Equipamento , Teste de Materiais , Metalurgia , Estresse Mecânico , Titânio/química
14.
Micron ; 150: 103142, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34509886

RESUMO

The aim of this work was to design, fabricate, test and validate a 3D-printed multisampling holder for multi-analysis by microcomputed tomography. Different raw materials were scanned by microcomputed tomography. The raw material chosen was used to fabricate the holder by 3D printing. To validate the multisampling holder, five teeth were filled with a high density-material and scanned in two ways: a single and a multisampling scan mode. For each tooth, the root canal filling volume, porosity volume, closed pore volume, and open pore volume were calculated and compared when the same tooth was scanned in the two sampling scan mode. ABSplus P430™ allowed a high transmission value (84.3 %), and then it was the polymeric material selected to fabricate the holder. In a single sampling scan mode, the scan duration for scanning five teeth was 87.42 min, contrasting with 21.51 min for a multisampling scan mode, which scanned five teeth at the same time. The scan duration time and the cost using a multisampling holder represented a reduction of 75 % and the data volume generated represented a reduction of 60 %. Comparing the two scan modes, the results also showed that the difference of root canal filling volume, porosity volume, closed pore volume, and open pore volume was not statistically significant (p > .05). The multisampling holder was validated to do multi-analysis by microcomputed tomography without significant loss of quantitative accuracy data, allowing a reduction in scan duration time, imaging cost, and data storage.


Assuntos
Ciência dos Materiais , Dente , Impressão Tridimensional , Obturação do Canal Radicular , Microtomografia por Raio-X
15.
Dent Mater ; 37(7): e399-e406, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33863567

RESUMO

OBJECTIVE: The water to powder ratio and method of mixing is important for the properties of hydraulic cements. For this purpose a number of clinicians prefer premixed materials. Dental manufacturing companies provide predosed materials, however the manufacturer instructions are not always adhered to. The aim of this research is to investigate physical and chemical alterations of the tricalcium silicate-based cement Biodentine when manipulated according to the manufacturer's instructions (control) or changing the doses and mixing of the material components. METHODS: 6 groups were constituted according to different mixing and dosing of powder and liquid. The hydrated cements were characterized using scanning electron microscopy (SEM), X-ray diffraction (XRD) and Fourier transform infrared spectroscopy (FT-IR). Calcium ion concentration of the leachate was also investigated. Assessment of the physical characteristics included setting time and microhardness. RESULTS: Microstructural differences were visible only in the Biodentine mixed manually with water, in which early hydration rate was also affected, with lower calcium ion release. Increase of Biodentine liquid increased the calcium ion release, but also increased the setting time. Manual manipulation required more liquid (both water and Biodentine liquid) added to the mixture to guarantee a similar consistency to the control. A decrease in setting time was also noted. All groups showed higher values of microhardness at 24 h compared to the freshly set materials. In the freshly set materials, there was an overall decrease in microhardness in all groups when compared to group control, particularly significant when increasing the dosage of Biodentine liquid. SIGNIFICANCE: When mixing Biodentine, altering the mixing procedure in terms of type and amount of liquid added to the powder and mixing device chosen has an effect on the physical, chemical and mechanical characteristics and surface topography of the material, when compared to Biodentine mixed according to the manufacturer's recommendations. Hence, the manufacturer's instructions should be strictly followed.


Assuntos
Compostos de Cálcio , Silicatos , Compostos de Alumínio , Combinação de Medicamentos , Teste de Materiais , Microscopia Eletrônica de Varredura , Óxidos , Espectroscopia de Infravermelho com Transformada de Fourier , Propriedades de Superfície , Difração de Raios X
16.
Eur Endod J ; 6(1): 56-71, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33762535

RESUMO

OBJECTIVE: Apical periodontitis develops when bacteria, or their by products, migrate from the infected root canal system space to the surrounding apical tissues. The objective of the present multi-center cross-sectional study was to analyze the prevalence of lateral radiolucency, apical root resorption and periapical lesions in 7 districts of Portugal using cone-beam computed tomographic (CBCT) assessment. METHODS: A total of 1,249 CBCT scans, from 11 dental clinics, were screened. Data regarding 22,899 teeth was included. For each tooth the recorded data was the presence of lateral radiolucency, apical root resorption, periapical lesions, previous root canal treatment, missed root canals, length of root canal filling (short, good or overfilling) and type of coronal restoration (intact tooth, non-restored, filling or crown). Differences between districts were tested using chi-squared. A P<0.05 was considered significant. RESULTS: The proportion of lateral radiolucency ranged between 0.0% (Aveiro, Braga and Coimbra) and 0.9% (Lisbon), while the prevalence of apical root resorption ranged from 0.0% (Braga and Coimbra) to 3.0% in Setubal. The nationwide proportion of lateral radiolucency was 0.4%, while for apical root resorption was 1.1%. The prevalence of periapical lesions varied from 4.1% (Braga) and 13.0% (Lisbon) with a nationwide proportion of 10.0%. Significant differences were noted between districts (P<0.05). CONCLUSION: The prevalence of lateral radiolucency and apical root resorption were low in all districts. Root canal filled teeth were associated with higher periapical lesions proportions than non-treated teeth. Independently of the assessed district, the periapical status may be influenced by both quality of the endodontic treatment and coronal restoration.


Assuntos
Reabsorção da Raiz , Tomografia Computadorizada de Feixe Cônico Espiral , Estudos Transversais , Humanos , Portugal/epidemiologia , Prevalência
17.
Aust Endod J ; 46(3): 452-457, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32896059

RESUMO

Internal root resorption is characterised by progressive loss of tooth substance initiating at the root canal wall as a result of clastic activity. This report describes a case of a perforating internal root resorption on a maxillary central incisor in a 25-year-old patient. The perforating internal root resorption was firstly diagnosed with periapical radiographs and assessed with full detail with the aid of CBCT, allowing determination of the extension and areas involved in the resorption lesion, as well as the treatment planning. According to these findings, a MTA barrier was performed on the root, -coronally to the resorption lesion, leaving the root apically to the resorption lesion untouched. Clinical findings and periapical radiographs indicated complete resolution of the radiolucency associated with the resorptive defect, with reestablishment of lamina dura along the root and occlusion of the lumen of the root canal in the apical segment, after a 5-year follow-up.


Assuntos
Materiais Restauradores do Canal Radicular , Reabsorção da Raiz , Adulto , Compostos de Alumínio , Compostos de Cálcio/uso terapêutico , Combinação de Medicamentos , Seguimentos , Humanos , Óxidos , Materiais Restauradores do Canal Radicular/uso terapêutico , Reabsorção da Raiz/diagnóstico por imagem , Reabsorção da Raiz/terapia , Silicatos/uso terapêutico
18.
J Endod ; 46(12): 1884-1893, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32898557

RESUMO

INTRODUCTION: This study aimed to compare the ProTaper Universal (PTU; Dentsply Maillefer, Ballaigues, Switzerland) system with 6 replicalike instruments regarding instrument design, mechanical performance, and alloy characteristics. METHODS: New rotary instruments (size 20/.07v) of PTU and 6 replicalike systems (EdgeTaper [EdgeEndo, Johnson City, TN], U-File [Dentmark, Ludhiana, India], Go-Taper Universal [Access, Shenzhen, China], Super Files [Flydent, Shenzhen, China], Multitaper [Proclinic Expert, Besançon, France], and Pluri Taper [Bestdent, Shenzhen, China]) (n = 329) were selected and evaluated regarding their design, mechanical performance, and metallurgical characteristics. The results were compared using the nonparametric Mood median test and 1-way analysis of variance with the significance level set at 0.05. RESULTS: Replicalike instruments were similar to PTU regarding design, maximum torque to fracture (P > .05), and ratio of nickel and titanium elements. Scanning electron microscopy revealed differences in the geometry of the tip and finishing surfaces. Time to fracture of Go-Taper Universal (50.0 seconds) was similar to PTU (44.0 seconds) (P > .05), but the U-File (63.5 seconds), Edge Taper (87.5 seconds), and Super Files (130 seconds) showed significantly higher values (P < .05). The highest maximum torque was observed in the Super Files instrument (P < .05), but no statistical difference was noted among the other instruments (P > .05). The angle of rotation before rupture of the Multitaper (574°) and Pluri Taper (481°) was higher than PTU (354°) (P < .05). Differential scanning calorimetric analysis showed clear differences on the transformation temperatures among the tested instruments. The R-phase start and finish temperatures of PTU were 11.0°C and -18.0°C, respectively. CONCLUSIONS: Overall, replicalike instruments were similar to PTU regarding the torsional resistance, geometric design, and near equiatomic proportions of nickel and titanium elements. In 3 of the 4 mechanical tests, the EdgeTaper (torque, angle of rotation, and bending load) and Go-Taper Universal (time to fracture, torque, and angle of rotation) systems were similar to PTU.


Assuntos
Ligas Dentárias , Preparo de Canal Radicular , China , Desenho de Equipamento , Falha de Equipamento , França , Índia , Teste de Materiais , Estresse Mecânico , Titânio , Torção Mecânica
19.
J Endod ; 46(8): 1136-1143, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32413441

RESUMO

INTRODUCTION: The aim of this study was to evaluate the cyclic fatigue resistance of 3 replicalike rotary instruments compared with their original brand systems using continuous rotation and optimum torque reverse (OTR) kinematics. METHODS: New F1 rotary instruments (n = 20 per group) from ProTaper Universal (Dentsply Maillefer, Ballaigues, Switzerland) and ProTaper Gold (Dentsply Maillefer) original brand systems were compared with 3 replicalike instruments (U-File [Dentmark, Ludhiana, India], Super Files [Shenzhen Flydent Medical, Shenzhen, China], and Super Files Blue [Shenzhen Flydent Medical]) regarding cyclic fatigue resistance. In each group, the selected instruments were randomly distributed into 2 subgroups (n = 10) according to the kinematics. In the rotary group (ROT), the instruments were activated with a continuous clockwise rotation (300 rpm, 1.5 Ncm), whereas in the OTR group, asymmetric oscillatory motion was performed setting the OTR function at 300 rpm and adjusting the torque limit at the minimum level using the TriAuto ZX2 motor (J Morita, Kyoto, Japan). The time to fracture was recorded and statistically compared according to the kinematics (ROT × OTR) and the instrument type (replicalike × original brand) using the independent sample t test (α = 0.05). Additionally, the metal alloy characterization of each system was performed by differential scanning calorimetry and energy-dispersive X-ray spectroscopy. RESULTS: Statistical analysis revealed significantly higher time to fracture for all rotary systems tested in OTR motion compared with continuous rotation (P < .05) with a mean percentage increase ranging from 52.1% (ProTaper Gold) to 156.7% (U-File). The replicalike instruments showed a significantly higher time to fracture compared with the respective original brand instruments in either ROT or OTR motion (P < .05). Replicas presented austenitic temperatures above the ones displayed by the original brands and an almost equiatomic ratio between nickel and titanium elements. CONCLUSIONS: OTR motion significantly improved the fatigue resistance of both original and replicalike systems. The replicas showed higher cyclic fatigue resistance than original brand instruments and higher transition temperatures to the austenitic phase.


Assuntos
Ligas Dentárias , Falha de Equipamento , Fenômenos Biomecânicos , China , Instrumentos Odontológicos , Desenho de Equipamento , Índia , Preparo de Canal Radicular , Rotação , Estresse Mecânico , Titânio
20.
J Endod ; 46(6): 771-777.e1, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32299702

RESUMO

INTRODUCTION: Fused root variations of the root canal system increase the complexity of the inner root canal system anatomy. The aim of the present study was to determine, in in vivo conditions, the proportion of periapical lesions in association with endodontically treated maxillary and mandibular molars with fused roots presenting previous root canal treatment by assessing preexisting data via cone-beam computed tomographic volumes. METHODS: A total of 1160 CBCT scans with an overall sample of 20,836 teeth were screened. A global count of 3701 maxillary molars and mandibular second molars were included in the study. The Cohen kappa test and interclass correlation coefficient tested the intra- and interrater reliability, respectively. The percentage of periapical lesions associated with molars with or without root fusion was determined. Proportions were expressed with 95% confidence intervals (CIs). The z test for proportions was used to analyze differences between subgroups, and an odds ratio was calculated in order to understand the association between periapical lesions and root configuration. RESULTS: Fused molars presented a prevalence of periapical lesions in endodontically treated teeth of 74.0% (95% CI, 65.2%-82.8%), whereas nonfused molars had a proportion of periapical lesions in root canal-treated teeth of 69.5% (95% CI, 65.2%-73.8%; P > .05). Endodontically treated molars with fused roots presented with 1.3 higher odds of being associated with periapical lesions than endodontically treated molars with nonfused roots. CONCLUSIONS: A tendency of a higher proportion of periapical lesions was found in the fused rooted molars with a history of root canal treatment when compared with nonfused teeth; however, no statistically significant difference was noted.


Assuntos
Cavidade Pulpar , Raiz Dentária , Tomografia Computadorizada de Feixe Cônico , Estudos Transversais , Dente Molar , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...